Sleep

Pauses the flow, then continues. Reach for it to wait until an embargo lifts before publishing, to wait two days and then send a reminder if nothing has changed, or to give another system a moment to catch up before the next step reads from it.

The Schedule field offers two ways to say how long.

Pauses for a span counted from the moment the step runs.

FieldDescription
DurationHow long to pause, in the chosen unit. Accepts a variable.
UnitMilliseconds, Seconds, Minutes, Hours or Days.

For example, Duration 2 and Unit Days after an Approval request, followed by a reminder on the path where nobody has answered.

A variable that resolves to something unusable, such as a duration that isn't a number or a timestamp in no known format, fails the step and names the value it couldn't use.

Time zones

A timestamp that carries an offset, such as 2026-09-18T14:30:00Z or 2026-09-18T14:30:00-04:00, already names a moment, as does an epoch number. Time Zone has no effect on either. It applies to a bare reading such as 2026-09-18 14:30:00 or 2026-09-18, which names a time but not where. Without it, such a value is read in the server's zone, which is rarely the zone the writer meant. Set it when another system reports local times and always from the same place. A zone the server doesn't recognize fails the step rather than guessing.

What later steps see​

Nothing of its own. The step passes its incoming payload through unchanged, and later steps keep referencing earlier outputs exactly as they would without it.

Behaviour​

While paused, the run holds without using resources, then resumes on its own. A pause draws nothing from the automation's one-hour execution budget, however long it lasts.

The step's run log records the pause as it starts, naming how long it waits and the moment it wakes, such as "Sleeping for 3 hours, 15 minutes; waking at Sep 25, 2026 2:42 PM." The wake time reads in your own time zone, whoever is viewing the run.

note

A run can live for 30 days in all. A Sleep For longer than that is flagged in the form, because the run would always time out at this step. See Limits.

Upgrading from the single Sleep For (ms) field

Sleep was previously one Sleep For (ms) field, always counted in milliseconds. Existing steps are converted to Sleep For with the unit set to Milliseconds, preserving the pause exactly. A step not opened since the upgrade keeps running at its original length until it is next saved.